1. Tee :Straight (Equal) Tee ,Reducer Tee
2.Wall Thickness: SCH5S-XXS
3.Size Range:
Welded: 1/2″-48″ (DN15-DN1200)
Seamless 1/2″-24″(DN15-DN600)
4.Standard
ASME B16.9, GB/T12459,GB/T13401,SH3408,SH3409,HG/T216345,HG/T21631, MSS SP-43, DIN2605,JIS B2313
5.Material
Grade: 304/L, 316/L,321/L, 317/L,347/H, 904L,310S, Duplex2205/S31803/F51,
2507/S32750/F53, ASTM A234, WPB/WPC/WP11/WP22
6.End Treatment
Bevel Ends , Plain Ends , or as per Clients Requirements
7.Surface Treatment: Transparent Oil
ASME B16.9 Butt weld Equal Tee
Standards: | ANSI – B 16.9 ASTM A403 – ASME SA403 – ‘Standard Specification for Wrought Austenitic Stainless Steel Piping Fittings’ ASME B16.9 – ‘Factory-Made Wrought Buttwelding Fittings” ASME B16.25 – ‘Buttwelding Ends’ MSS SP-43 – ‘Wrought and Fabricated Butt-Welding Fittings for Low Pressure, Corrosion Resistant Applications’ |
Schedule: | Sch 5 TO Sch XXS. |
Variations: | Welded & Seamless |
Sizes: | 1/2” TO 36” (SEAMLESS UPTO 24”) (WELDED 8” TO 36” ) |
Materials: | Monel, Nickel, Inconel, Hastalloy, Titanium, Tantalum, Stainless Steel, Alloy Steel, Carbon Steel, Cupro-Nickel 90/10 & 70/30 Stainless Steel ASME / ASTM SA / A403 SA / A 774 WP-S, WP-W, WP-WX, 304, 304L, 316, 316L, 304/304L, 316/316L, DIN 1.4301, DIN1.4306, DIN 1.4401, DIN 1.4404 |
Type: | Butt Weld (BW) |
Thickness: | Schedule 5S, 10S, 20S, S10, S20, S30, STD, 40S, S40, S60, XS, 80S, S80, S100, S120, S140, S160, XXS and etc. |
Dimension: | Outside diameter : 1/2″ à 24″ (21,34 – 609,5 mm) Thickness : SCH 5S, 10S, 40S (STD), 80S (XS), 160, XXS (1,65 – 59.51 mm) |
Tee fittings are often used in horizontally branched pipes. We are often accustomed to taking over the management from the bottom of the supervisor. When the three-way pipe is used to transport the liquid medium, the A860 WPHY60 is three-way, and the three-way pipe should face upwards to prevent the condensate from blocking the pipe when the gas pipeline is branched in the horizontal direction. In particular, the steam pipe branch should be taken out from above. The confluence tube of the vacuum tube, ASME B16.9 three-way, should merge in the same direction. If there are two branch vacuum pipe confluences, they should be arranged alternately to avoid docking. The low-pressure combustible gas pipeline connected to the flare gas manifold should be ramped downstream and over the ball to avoid pressure drops and to facilitate fluid flow. Although the cost of the branch pipe reinforcement plate material is lower than that of the three links, the construction requirements are relatively high. The A860 WPHY70 three-way connection makes it difficult to control the construction quality. In view of the overall price performance ratio, it is recommended that there should be a three-way link for the finished three-way links, and that there should be no branch links to strengthen the board when there are no three links.
Nominal Pipe Size | Outside diameter at bevel |
Center-to-End | |
---|---|---|---|
Run (C) | Outlet(M) | ||
1/2″ | 21.3 | 25 | 25 |
3/4″ | 26.7 | 29 | 29 |
1″ | 33.4 | 38 | 38 |
1 1/4″ | 42.2 | 48 | 48 |
1 1/2″ | 48.3 | 57 | 57 |
2″ | 60.3 | 64 | 64 |
2 1/2″ | 73.0 | 76 | 76 |
3″ | 88.9 | 86 | 86 |
3 1/2″ | 101.6 | 95 | 95 |
4″ | 114.3 | 105 | 105 |
5″ | 141.3 | 124 | 124 |
6″ | 168.3 | 143 | 143 |
8″ | 219.1 | 178 | 178 |
10″ | 273.0 | 216 | 216 |
12″ | 323.8 | 254 | 254 |
14″ | 355.6 | 279 | 279 |
16″ | 406.4 | 305 | 305 |
18″ | 457.0 | 343 | 343 |
20″ | 508.0 | 381 | 381 |
22″ | 559.0 | 419 | 419 |
24″ | 610.0 | 432 | 432 |
The dimensions are in millimeters